logo

Reverse Osmosis Plant & Technology

Truewaters Solutions is India’s trusted name for turnkey industrial RO plants. From compact 50 LPH drinking-water units to 500 m³/h high-recovery process-water systems, our engineers customise every skid to your feed-water chemistry, flow rate and footprint. Each plant integrates RO, UF, UV, activated carbon and smart automation to deliver a continuous supply of Truewater™—pure, great-tasting water your people and processes can rely on.

How an Industrial RO Plant Works

Z

Pre-filtration – Disc & Multigrade Filters

Remove large colloids, dirt and turbidity, shielding downstream membranes.

Z

Activated Carbon Filtration

Eliminates chlorine, colour, odours and organic traces.

Z

Antiscalant Dosing

Precision metering pump prevents hardness scale on RO membranes.

Z

Micron Cartridge (≤ 5 µm)

Polishes feed water for final particulate removal.

Z

RO Membrane Separation

Rejects up to 99 % dissolved salts, heavy metals, bacteria and viruses.

Z

UV Sterilisation & Rotameter Monitoring

Real-time flow checks and final microbial disinfection.

Z

CIP Cleaning System

Automated clean-in-place restores membrane flux, extending service life.

Integrated Water-Treatment Technologies

Reverse Osmosis (RO) purification

Reverse Osmosis (RO) purification

Ultra-Filtration (UF) polishing

Ultra-Filtration (UF) polishing

UV-C disinfection

UV-C disinfection

Candle & depth cartridge filters

Candle & depth cartridge filters

High-iodine activated carbon blocks

High-iodine activated carbon blocks

Why Choose Truewaters Solutions

Why Choose Truewaters Solutions

Lowest Life-Cycle Cost – up to 15 % lower energy use and minimal consumables

Purity Guaranteed – online TDS meters verify 99 % salt rejection

Smart Automation – Siemens PLC + HMI, remote diagnostics, WhatsApp alerts

Space-Saving Skids – plug-and-play, forklift-friendly frames fit tight utilities

Quick Maintenance – tool-less filter change; spares dispatched within 24 hours

Made-in-India Reliability – ISO 9001-certified factory and pan-India service network

Capacities & Key Applications

Sector Typical Capacity (LPH) Primary Use
Boiler & Power Plants 5,000 – 50,000 Boiler feed, condensate polish
Automobile & Paint Shops 2,000 – 20,000 Spot-free rinse, surface prep
Oil, Gas & Mining 10,000 – 100,000 Desalination, utility water
Hotels & Resorts 1,000 – 5,000 Guest drinking water, kitchen
Schools & Hospitals 500 – 5,000 Safe potable water

Frequently Asked Questions

What maintenance does an industrial RO plant need?

Routine maintenance keeps an industrial RO plant running at peak efficiency:
• Pre-filter cartridges: replace every 3–6 months to block sediment and chlorine.
• CIP (Clean-in-Place): flush membranes with approved chemicals every 6–12 months to remove scale and bio-fouling.
• UV lamps: swap annually to guarantee final disinfection.
Sticking to this schedule maximises membrane life and lowers operating cost.

How much wastewater (RO reject) does an industrial RO plant generate?

Our high-recovery RO designs limit reject to just 20–30 % of feed water. Adding an RO-reject recycling loop can push overall water recovery above 85 %, cutting disposal costs and meeting zero-liquid-discharge goals.

Can automation be retrofitted into an existing RO system?

Absolutely. Truewaters retrofit kits add:
• PLC + HMI control for unattended operation
• VFD-driven pumps for energy savings
• IoT sensors that send performance alerts via WhatsApp/SMS
Installation requires minimal piping changes, giving legacy systems the same smart features as new builds.